Parent Artery Reconstruction for Large or Giant Cerebral Aneurysms Using the Tubridge Flow Diverter: A Multicenter, Randomized, Controlled Clinical Trial (PARAT)

Editor’s Choice This was a prospective, multicenter, randomized trial conducted at 12 hospitals throughout China. Enrolled adults with unruptured large/giant intracranial aneurysms were randomly assigned (1:1) to receive either Enterprise stent-assisted coiling or Tubridge flow diverter implantation. The primary end

Evaluation of the Sensitivity of Inhomogeneous Magnetization Transfer (ihMT) MRI for Multiple Sclerosis

Editor’s Choice Twenty-five patients with relapsing-remitting MS and 20 healthy volunteers were enrolled in a prospective study with a protocol including anatomic imaging, standard magnetization transfer, and inhomogeneous magnetization transfer imaging. Magnetization transfer and inhomogeneous magnetization transfer ratios measured in

Iron-Insensitive Quantitative Assessment of Subcortical Gray Matter Demyelination in Multiple Sclerosis Using the Macromolecular Proton Fraction

Editor’s Choice Fast macromolecular proton fraction mapping is a recent quantitative MR imaging method for myelin assessment. Macromolecular proton fraction and T2* maps were obtained from 12 healthy controls, 18 patients with relapsing-remitting MS, and 12 patients with secondary-progressive MS

Iodine Extravasation Quantification on Dual-Energy CT of the Brain Performed after Mechanical Thrombectomy for Acute Ischemic Stroke Can Predict Hemorrhagic Complications

Editor’s Choice Eighty-five consecutive patients who underwent brain dual-energy CT immediately after mechanical thrombectomy for acute ischemic stroke between August 2013 and January 2017 were included. Two radiologists independently evaluated dual-energy CT images for the presence of parenchymal hyperdensity, iodine

High Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted MR Images: Comparison between Gadobutrol and Linear Gadolinium-Based Contrast Agents

Editor’s Choice This is a retrospective analysis of 59 patients who received only gadobutrol and 60 patients who received only linear gadolinium-based contrast agents. Linear gadolinium-based contrast agents included gadoversetamide, gadobenatedimeglumine, and gadodiamide. T1 signal intensity in the globus pallidus,

Noninvasive Assessment of Intracranial Pressure Status in Idiopathic Intracranial Hypertension Using Displacement Encoding with Stimulated Echoes (DENSE) MRI: A Prospective Patient Study with Contemporaneous CSF Pressure Correlation

Editor’s Choice Nine patients with suspected elevated intracranial pressure and 9 healthy control patients were included in this prospective study. Control patients underwent DENSE MR imaging through the midsagittal brain while patients underwent DENSE MR imaging followed immediately by lumbar

Feasibility of Brain Atrophy Measurement in Clinical Routine without Prior Standardization of the MRI Protocol: Results from MS-MRIUS, a Longitudinal Observational, Multicenter Real-World Outcome Study in Patients with Relapsing-Remitting MS

Editor’s Choice Brain atrophy outcomes of 590 patients were analyzed by the percentage brain volume change measured by structural image evaluation with normalization of atrophy on 2D-T1WI and 3D-T1WI and the percentage lateral ventricle volume change, measured by VIENA on